CN - Primary Replacement Nut

The CN Series Stretch-to-Load ClampNut is the modern day replacement of Multi-Jack-Screw Nuts and Hydraulic Bolt Tensioners for a hands-free safe bolt load accuracy within 7%

CN Series Clamp Overview

CN Series Clamp

JETYD, HYTORC Castle nut designed for tight quarter, spacing or bolt protrusion bolting commonly used in chemical processing facilities on boiler feed pumps and portal bolts.

The CN series clamp line covers a wide range of sizes and applications. The CN Series clamp was originally specified to replace fasteners that were operated with hydraulic bolt tensioners. The through bolt design of the CN Series clamp makes them an appropriate choice for applications with high stud extensions. The outside diameter of a CN Series clamp is approximately the cross corner dimension of a standard heavy hex nut.

CN Series clamps are typically specified for applications with minimal radial constraints. The relatively thick outer sleeve of a CN Series clamp minimizes stresses and allows them to handle high loads at elevated temperatures.


CN Series Clamp DiagramThe CN Series clamp is composed of three components:

  • Outer sleeve
  • Inner sleeve
  • Washer

As the outer sleeve turns (blue arrow), the inner sleeve moves upwards (red arrow). The washer spline rotationally couples the inner sleeve with the washer preventing the inner sleeve from turning while providing a solid reaction point for turning the outer sleeve.


back to menu

CN Series Clamp Features & Benefits

CN Series Clamp

BENEFITS

  • Reaction free bolt tensioning
  • Pure tensile loads
  • 100% elimination of galling on flange and stud surfaces
  • Highest bolt tension accuracy and reliability available

FEATURES

  • The CN Series ClampNut is used in conjunction with a coaxial action/reaction pneumatic or hydraulic torque tool.
  • Through bolt design allows fit on any stud projection
  • Robust outer sleeve minimizes stresses
  • Castellated outer sleeve - eliminates need for oversize socket drive
    CN Series Clamp
    CN Series clamp application powered by J-Gun tool.
  • Standard drives available for all applicable tools
  • Low, Standard, Medium & High temperature ratings available
  • All thread forms available

back to menu


CN Series Clamp Specifications

CN Series Clamp Diagram
  1. Identify Blank Size from table below. (Cross reference this number from the row with the proper Nominal Stud Size)
  2. Verify that the Outside Diameter for this Blank Size will not interfere with adjacent nuts or other application constraints. (Such as a small counter bore)
  3. Verify that the Max Load and Max Stroke are sufficient for the application.
  4. Verify that there is sufficient overhead clearance for access with tooling.
  5. Fill out the part number information on the adjacent page.

BLANK SIZE

This is the basic body size for the CN Series clamp. Any desired thread up to the Nominal Stud Size can be cut into each Blank Size.

SIZE CODE

Size Code is the JETYD code used to indicate the Nominal Stud Size. The first digit signifies the whole number of inches. The second two digits signify the number of 1/16 of an inch. (108 = 1”+ 8/16 = 1½”)

NOMINAL STUD SIZE

This is the largest stud that will fit a particular Blank Size. All CN Series clamp blanks can be specified with threads smaller than the Nominal Stud Size.

HEIGHT

This is the overall height of the standard TN Series clamp for this Blank Size. Tooling will require additional overhead space. This is not the Height of the stud protrusion. Consult with a JETYD Applications Engineer when custom taller clamps are required.

MAX STROKE

CN Series clamps have maximum stroke lengths that are limited by the height of the splined washer. More stroke may be needed to accommodate gasket compression or an extraordinarily long joint length. Consult with a JETYD Applications Engineer for special extended stroke clamps.

MAX LOAD

This is the recommended maximum target load for each fastener on the application. This load is conservative as it allows margin for removal. It is based on 80% yield for ASTM A193 B7-B16 & 8TPI bolt material for the listed Nominal Stud Size. Consult with a JETYD Applications Engineer when higher loads are required.

BLANK
SIZE
SIZE
CODE
NOMINAL STUD SIZE OUTSIDE
DIAMETER
(in)
HEIGHT
(in)
MAX
STROKE
(in)
MAX
LOAD
(in)
INCH METRIC
01 14 7/8 M22 1.66 1.429 0.201 38,766
02 100 1 M24 1.811 1.559 0.220 50,857
03 102 1 1/8 M27 2.038 1.754 0.247 66,364
04 104 1 ¼ M30 2.264 1.949 0.275 83,933
05 106 1 3/8 M33 2.491 2.144 0.302 103,562
06 108 1 ½ M36 2.717 2.339 0.330 125,251
07 - - M39 2.943 2.533 0.357 130,951
08 110 1 5/8 M42 3.17 2.728 0.384 149,001
09 112 1 ¾ M45 3.396 2.923 0.412 174,812
10 114 1 7/8 M48 3.623 3.118 0.439 202,683
11 200 2 M52 3.925 3.378 0.476 232,615
12 204 2 ¼ M56 4.226 3.638 0.513 298,661
13 208 2 ½ M64 4.83 4.157 0.586 337,431
14 212 2 ¾ M70 5.283 4.547 0.641 412,102
15 - - M72 5.434 4.677 0.659 438,382
16 300 3 M76 5.736 4.937 0.696 494,230
17 - - M80 6.038 5.197 0.732 547,981
18 304 3 ¼ - 6.34 5.457 0.769 583,816
19 308 3 ½ M90 6.793 5.846 0.824 680,859
20 312 3 ¾ M95 7.17 6.171 0.870 785,360
21 700 4 M100 7.547 6.496 0.915 897,318
22 404 4 ¼ M110 8.302 7.146 1.007 802,685
23 408 4 ½ M115 8.679 7.47 1.053 902,848
24 412 4 ¾ M120 9.057 7.795 71098 1,008,889
25 500 5 M125 9.434 8.12 1.144 1,120,837
26 504 5 ¼ M130 9.811 8.445 1.190 1,238,662
27 508 5 ½ M140 10.566 9.094 1.281 1,362,375

back to menu



CN Series Clamp Facts & Information

CN Series Sample Data

Materials

CN Series material selection is based on the service temperature rating of the clamp. Please see the Clamp Service Temperature section of the JETYD catalog for a detailed specification on the materials used for each component of the clamp.

Application Tips

Measurement of the thread pitch is the most error prone portion of clamp specification. The easiest way to measure pitch is with a pitch gauge. Alternatively please provide JETYD with a sample of the stud.

Special coatings can cause dimensional variations on studs and nuts, i.e. Galvanized studs often have a coating build up that effectively changes the thread size. If the application studs have coatings, special care should be taken to determine the actual thread size. A standard UN nut will not fit a standard UN stud thread if a thick coating is applied. In these situations it will typically be best to supply JETYD with a sample stud.

Available Drives

Click here to see the Clamp Drive section. CN Series Sample Data

Load Charts

All CN Series clamps are available with a Load Chart. Load Charts provide data points showing the tool’s hydraulic pressure vs. the bolt load that will be attained. A load chart can be created for any tool with any clamp.

Specials

When components fall outside of the boundaries of our standard parts’ numbering system, they become Specials. The following list exemplifies some of the variations that could make your clamp specification a Special:

  • Modified or non standard thread sizes such as those for oversize studs
  • Extended or shortened clamp length requirements
  • Extended stroke requirements
  • Special coating requirements such as galvanizing or Xylan
  • Non-standard materials, testing or certification requirements

Specials will be assigned a special part number. Please contact a JETYD application engineer when specifying non-standard clamps.

back to menu

CN Series Clamp Applications

Common CN Series applications include:

  • chemical processing facilities
  • boiler feed pumps
  • portal bolts

Click on an image for a larger view


back to menu

CN Series Clamp Demonstration Video




back to menu


Call 877-GO-JETYD or click here to contact us for a free on-site demonstration.